This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| ref:awg-iec-wire [2025/04/14 12:05] – ↷ Page moved from reference:awg-iec-wire to ref:awg-iec-wire Alan Shea | ref:awg-iec-wire [Unknown date] (current) – removed - external edit (Unknown date) 127.0.0.1 | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | ~~NOTOC~~ | ||
| - | ======AWG-IEC Wire Gauges==== | ||
| - | American Wire Gauge (AWG) and IEC (mm< | ||
| - | |||
| - | <WRAP group> | ||
| - | <WRAP column 400px> | ||
| - | |||
| - | ^ AWG/\\ kcmil ^ Area Circular Mils ^ Amperes | ||
| - | ^ ::: ^ ::: ^ TW/UF (60C) ^ THHW (75C) ^ THHN (90C) ^ ::: ^ | ||
| - | | 18 | 1620 | -- | ||
| - | | 16 | 2580 | -- | ||
| - | | 14* | ||
| - | | 12* | ||
| - | | 10* | ||
| - | | 8 | ||
| - | | 6 | ||
| - | | 4 | ||
| - | | 3 | ||
| - | | 2 | ||
| - | | 1 | ||
| - | | 1/0 | ||
| - | | 2/0 | ||
| - | | 3/0 | ||
| - | | 4/0 | ||
| - | | 250 | ||
| - | | 300 | ||
| - | | 350 | ||
| - | | 400 | ||
| - | | 500 | ||
| - | | 600 | ||
| - | | 700 | ||
| - | | 750 | ||
| - | | 800 | ||
| - | | 900 | ||
| - | | 1000 | 1000, | ||
| - | |||
| - | * Maximum overcurrent protection: \\ #14 = 15A, #12 = 20A, #10 = 30A | ||
| - | |||
| - | //NEC 2007, Chap 9, Table 8, \\ via Ugly's Electrical Ref 2008, pp71, 73// | ||
| - | </ | ||
| - | |||
| - | <WRAP column 270px> | ||
| - | ^ IEC mm2 ^ Circular Mils ^ Amperes | ||
| - | | ::: | ::: | ||
| - | | 0.5 | 987 | -- | ||
| - | | 0.75 | ||
| - | | 1.5 | 2961 | ||
| - | | 2.5 | 4935 | ||
| - | | 4 | 7896 | ||
| - | | 6 | 11, | ||
| - | | 10 | ||
| - | | 16 | ||
| - | | 25 | ||
| - | | 35 | ||
| - | | 50 | ||
| - | | 70 | ||
| - | | 95 | ||
| - | | 120 | 236, | ||
| - | | 150 | 296, | ||
| - | | 185 | 365, | ||
| - | | 240 | 473, | ||
| - | | 300 | 592, | ||
| - | |||
| - | * //IEC 60364-5-52, Table A.52.4// | ||
| - | * Fig. G20, http:// | ||
| - | </ | ||
| - | <WRAP clear></ | ||
| - | <WRAP column 450px> | ||
| - | |||
| - | ===Short-time Withstand Rating=== | ||
| - | Copper conductors and bolted connections withstand rating: | ||
| - | * 1 Ampere for 5 seconds per: | ||
| - | * 30 circular mils (bare wire) | ||
| - | * 42.25 circular mils (75°C insulated wire) | ||
| - | //NEC 250-94, 250-95// | ||
| - | |||
| - | ===Conversions=== | ||
| - | * kcmil = Square Inches x 1273 | ||
| - | * kcmil = Square Millimeters x 1.974 | ||
| - | * mm2 = kcmil x 0.5067 | ||
| - | |||
| - | //2007 Erico Cadweld Catalog, Technical Information (page B-4)// | ||
| - | </ | ||
| - | <WRAP column 290px> | ||
| - | |||
| - | {{ : | ||
| - | </ | ||
| - | </ | ||
| - | <WRAP clear></ | ||
| - | \\ \\ | ||
| - | [[wp> | ||
| - | |||
| - | [[https:// | ||
| - | |||
| - | |||
| - | ---- | ||
| - | ===Downloads== | ||
| - | {{filelist>: | ||
| - | |||
| - | <wrap hide> | ||
Copyright © Alan Shea, 2011-2025